Server Hosting and Support
Overview of Service
Franklin OIT offers both physical server hosting and support.
Physical Server Hosting & Support
Franklin College leases rack space within the central Boyd Data Center Hosting to meet increasing demand for services that comply with physical security requirements for relevant laws and granting agencies. The center was renovated in 2006 to include a 4,300 square foot addition (for a total of 16,000 sq ft) and is supported by an enterprise class generator, remote camera monitoring, secure card access, 2 commercial UPS units, and a gas fire-suppression system. This provides a stable, cost-effective location for personnel to host their physical server equipment. In addition to the physical hosting, Franklin OIT provides limited support for installation, network, and support for a minimal cost to clients.
Virtual Server Hosting & Support
Franklin College leverages the Virtual Server Hosting offered by EITS. This provides a stable, cost-effective solution for projects and services requiring a specialized system to meet the needs of the project. An annual support contract with Franklin OIT is required for this service so the virtual server is regularly patched, service and security managed, and to ensure the system meets campus compliance requirements.
Benefits of Services
Benefits for Hosting in Boyd Data Center
Peace of mind for securing Sensitive and Critical Data
Reduction in downtime due to Generator Backup, UPS and extra Air Handlers
Fire Suppression/Physical Security Coverage
Freeing up space in your facilities
Freeing up monitoring staff for other functions
Flexibility and cost efficiency for System Administration support through Franklin OIT or EITS
Benefits for Virtual Hosting Services through EITS
No need to purchase or upgrade hardware every 5-7 years.
Purchase only what is needed, System resources (memory, processor, and storage) can be expanded as-needed.
EITS maintains the hardware, networking, software licensing, and necessary service platform components.
Franklin OIT maintains the system Operating System, monthly patching, user account and group management, basic security (firewall, user), and required MDEp2 security software.
Requesting Use and Support
New Clients
Franklin College faculty and staff can request server hosting by contacting the Franklin OIT Help Desk.
Existing Clients
Franklin College faculty and staff can request support for servers by contacting the Franklin OIT Help Desk.
Current Rates for Service
Service | Fees |
|---|---|
Physical Server Installation and Configuration | $240 / system (one-time) |
Physical or Virtual Maintenance and Support | $720 / system (annual) |
Virtual Server Pricing (via EITS) | |
Additional Services | One-time Fees |
Custom configurations | $60 / hour |
Server compliance certification | $320 / system |
Client Responsibilities
Clients are responsible for the following:
Initiate requests for new service, change on existing service, or support for services via the Franklin OIT Help Desk.
Adhere to any hosting requirements found in Additional Information for Service section.
Purchase of any required items; including but not limited to hardware including racking hardware, software, support services, warranty, cabling, licensing, or fees.
Notify Franklin OIT if a server is being decommissioned or the point of contact changes.
Develop data management plans, disaster recovery plans, and business continuity plans as applicable.
This includes establishing and covering the costs of a backup solution.
Additional information about Data Management is available in the Franklin OIT Service Level Agreement
Franklin OIT offers backup services for servers. For more information visit our service listing for backup services
Training users on how to utilize any applications running on the server
Troubleshooting, maintenance, and security of any user-run applications, scripts, or software installed on the server
Adhering to any relevant Franklin OIT, UGA, or USG policies.
Information about which policies may apply can be found in the Franklin OIT Service Level Agreement.
OIT Responsibility
Franklin OIT has particular responsibilities to every client that are detailed in our Franklin OIT Service Level Agreement.
For Server Hosting and Support, Franklin OIT is responsible for the following:
Respond to initial client request for information, use of, or support for this service
Meet with the client to discuss needs and provide a detailed list of recommendations
Provide documentation to detail the work Franklin OIT will perform and confirm when that work is completed
Provide any additional documentation that may be required to clarify expectations
Provide adequate notice to clients of any proposed rate changes
When maintenance and support is included Franklin OIT is also responsible for:
User management
Maintenance and patching of the operating system and hardware
Troubleshooting of reported or monitored system-level issues
Timely communication about system outages or maintenance
You can find more information on the UGA Boyd Data Center hosting, facilities, and benefits by visiting the Boyd Datacenter Hosting Information Page.
Supported operating systems include CentOS / RedHat Enterprise Linux 8+, and Windows Server 2016+
Please note the below requirements for use of the Boyd Data Center Hosting:
All servers must contain adequate rack-mount support hardware such as rails and cable management arms.
Rails should support a standard 4-post rack design with square mounting holes.
Franklin OIT will NOT provide shelves or other rack mounting hardware.
We recommend using Dell Rapid Rails or other fast/tool-less rack mounting rails for easier installation and management.
All servers must have the ability for complete 'lights out' hardware remote management.
Hardware-level remote management generally mitigates the need to have physical access to a piece of hardware for the purposes of OS install or other direct hardware management and power state changes.
Franklin OIT recommends Dell iDRAC Enterprise, HP iLO, or equivalent IPMI remote management hardware.
Systems installed in the Franklin OIT racks in Boyd are only physically accessible by appointment Monday - Friday 8am-5pm or during emergencies when coordinated with SMT staff.
Personnel will be escorted or otherwise supervised by an SMT member during visits.
An hourly service fee may be assessed on a case-by-case basis and will be discussed with the client per instance.
Systems must be enterprise-class hardware and it is recommended to have built-in redundancy including:
Failover or redundant power supplies (required)
Redundant arrays of disks (RAID) (recommend using hardware vs. software RAID)
A hot spare is recommended to avoid the need to make emergency/after-hours visits.
Dual network cards (or greater)